CDTech LCD touch screen

display / touch / bonding solutions

Cosmetic Limit Samples and Boundary Samples: Agreeing What Counts as a Defect Before the First Lot

Author: CDTech Publish Time:  Origin:

Cosmetic acceptance is where display programmes argue most and document least. A drawing can call a scratch unacceptable, but the inspector is judging a reflection, a background and an angle, and two reasonable people can reach different verdicts on the same panel. Limit samples turn that judgement into a comparison: a physical reference both parties have signed, held under conditions the drawing states. This article sets out how to build a set that covers the defect classes a display produces, and how to keep it usable.

Why a dead-pixel count cannot settle a cosmetic dispute

Because a count ignores position, size and adjacency.

Two panels can carry the same count and look different. A dot at the centre of a black field is obvious; the same dot near the border may never be seen.

A pixel rule is a useful screen and a poor contract. It says how many, not where, not how close together, and not whether a sub-pixel or a whole pixel is at fault. Two adjacent dark dots in the middle of the active area read as a smudge, while the same count scattered near the edge disappears.

Most cosmetic defects are not countable at all. Mura, light leak and surface marks have no unit, so a numeric clause leaves them to judgement. The practical answer is a hybrid: numbers where counting is meaningful, samples where judgement is not. The ISO pixel defect classifications give a starting framework, and this site's guide to defect diagnosis and acceptance covers how the categories are distinguished.

Defect classes that need separate limit samples

One sample set for everything is worse than none, because a single approved panel teaches the inspector nothing about which feature was approved. Build the set class by class, so each comparison tests one attribute against one reference.

The classes are stable across projects: point defects (bright and dark dots, including sub-pixel cases), line defects (vertical and horizontal, always-on and always-off), surface defects on the cover glass or polariser (scratches, digs, polish marks), foreign material in or under the bond, mura and unevenness, light leak and edge seal appearance, and touch artefacts such as Newton rings or visible ITO traces on a capacitive panel.

For each class the set needs an acceptance boundary and a rejection boundary, ideally a pair of the same defect type. A single accepted example leaves the inspector guessing how much worse is still acceptable. Assembly-level defects such as solder appearance at a flex attach follow the visual criteria in IPC standards, and the display selection guide covers how panel type and cover construction change the class list.

Which viewing conditions decide whether a defect exists

Illuminance, distance, angle and background.

The same panel passes in a bright office and fails in a dark room. Conditions are part of the criterion, so every sample must carry them.

A sample judged under one light and applied under another is not a control. The condition card should state the illuminance at the surface, the viewing distance, the angle, and the display state used for the check.

ConditionWhat to stateWhy it changes the verdict
IlluminanceLux at the panel surfaceScratches and dust appear above a threshold
Viewing distanceDistance in mm, eye positionDots and mura disappear with distance
AngleNormal, or a stated tiltLight leak and polariser marks move with angle
Display stateWhite, grey, black, RGB fieldsBright dots show on black, mura on grey

Inspection time belongs on the card too: an inspector who stares finds defects a user would never see. The ASTM standards for appearance measurement show how much the light source changes a reading.

Bright dot, dark dot and cluster rules beyond the count

The rules that survive production describe geometry rather than quantity. Position matters: a dot inside the primary viewing area is judged differently from one in a bezel-covered margin, and the drawing should say where those boundaries fall. Adjacency matters more than count, because two touching defects read as one larger defect.

Sub-pixel behaviour is the detail most often missed. A bright sub-pixel on a black field is more visible than a dark one, and a stuck green sub-pixel changes the colour of a white area rather than adding a spot. The clause should say whether the count is of pixels or sub-pixels, and how a defect that changes with the field colour is classified.

Samples make those words usable. A pair showing one accepted dot and one rejected dot at the stated distance does more than a paragraph. Label which is which on the reverse of each sample.

Line, scratch and foreign-material samples at the boundary

Linear defects trade length against width, and a maximum length with no width condition is exploited in both directions. The clause should pair the two dimensions and say where the measurement is taken.

Depth is the second axis, and the one a photograph cannot carry. A scratch in a surface coating catches light at a low angle and may polish out; a scratch into the polariser is permanent. The samples should represent both, with the lighting that exposes the difference written on the card.

Foreign material needs its own treatment: location and mobility matter as much as size. A particle under the bonded area is a bright spot at one angle and a dark speck at another, while a particle on the outer surface can be cleaned. Include an accepted particle, a rejected one, and one for the cleaning test.

7.0inch 800x480 TFT LCD display with Capacitive touch panel
A 7.0inch 800x480 TFT LCD display with capacitive touch panel. On a touch module, cover-glass scratches and Newton rings need their own boundary samples, not a share of the pixel rule.

Mura and unevenness: where a photograph fails

Mura is the class that most often defeats documentation. It is a low-contrast, large-area variation that a camera renders differently from the eye: sensor noise, white balance, compression and lens angle all change the image, and a photograph that looks acceptable on one screen looks defective on another.

What works instead is a physical sample judged at the stated distance on a mid-grey field, with the boundary agreed in person. Where a numerical guide is wanted, a graded grey reference or a set of panels at increasing severity gives the inspector a scale rather than an opinion, and it survives a change of camera.

The condition card matters most here. Mura visibility changes with illuminance and with the grey level used, so the sample must state both. Two engineers looking at the same panel on different grey fields will describe different defects, and neither is wrong. The IEC webstore carries the display measurement standards behind those field definitions.

Light leak and edge seal samples to agree early

Edge defects sit between cosmetic and functional, and they are cheapest to agree before tooling. Corner light leak, a seal visible through the cover glass, squeeze-out and a gap that varies along one edge are normal until someone decides how much is too much.

The samples should show both ends of each: bleed visible only in a dark room, bleed visible in office light, and a seal line whose width varies along the edge. State the display state, since light leak is judged on a black field with the backlight on, and say whether the room must be darkened.

3.5 inch 320*240 IPS TFT LCD display with Resistive Touch Panel
A 3.5 inch 320*240 IPS TFT LCD display with resistive touch panel. A resistive stack adds a flexible top layer, so seal and light leak samples should be judged with the touch layer fitted.

A limit sample set by defect class

A working set is small enough to use and complete enough for the drawing. The checklist below keeps it that way; the number of samples per class follows the classes on the drawing, not a target piece count. Where a sampling plan is quoted instead of full inspection, the MIL-STD documents in the ASSIST archive set out how sample size and acceptance number relate.

  • One master set with the supplier, and one working set per inspection site.
  • Accept and reject pair for each class the drawing controls.
  • Class label on every sample: type, zone, verdict, sample ID.
  • Condition card: illuminance, distance, angle, background, display state, duration.
  • Drawing and specification revision the set was agreed against.
  • Photographs for identification only, never as the acceptance reference.
  • Storage conditions: dark, dust-free, stable temperature.
  • Sign-off record naming both parties and who may change the set.

Samples should be handled like gauge blocks, not stock: kept covered, checked for damage or fading, and replaced when a reference no longer matches its defect.

Sign-off, storage and revision control for limit samples

A sample nobody signed is an opinion with a part number. Sign-off should come from the customer's quality function and the supplier's quality manager, on a document naming the sample IDs, the drawing revision and the conditions, so the set can be reconstructed if it is lost.

Storage is the quiet failure. Samples left on a windowsill fade, samples in a drawer collect dust, and samples handled without gloves acquire the defects they are meant to define. Keep the master set covered, in a defined location, with a named custodian and a log of who removed it. Where the customer keeps a set, check both against each other at least once a year.

Revision control runs on the usual triggers: a drawing change, a new panel source, a change of cover glass or coating, or a new customer requirement. Superseded samples must be withdrawn rather than left in the inspection area, and the records behind them follow the scope on the quality certifications page.

Writing the acceptance clause so arbitration is possible

An acceptance clause earns its keep on the day the parties disagree. It should define the defect classes in the words the sample set uses, reference the sample IDs and revision, state the viewing conditions, and say which document wins when text and sample conflict. Say it explicitly: the sample governs and the text explains.

The clause should also name the inspection stage, since a criterion applied at final assembly is not the same as one applied after shipping. Name the sample size and the record, and treat appearance approval as a formal submission rather than a meeting, which is how the AIAG appearance approval report treats it.

Finally, write the dispute path before it is needed: who inspects first, what evidence is exchanged, how a third party is selected, and which sample version applies. A clause with that paragraph ends arguments in days rather than quarters, and the quality and reliability guide covers the inspection practice it should reference.

If your team is writing cosmetic acceptance criteria for a display module and needs the sample set agreed before the first lot, CDTech can supply graded reference panels, condition cards and the inspection record alongside the quotation. Send the defect classes and viewing conditions you intend to control to [email protected], or use the contact page to set out what the drawing needs to say.

FAQ

How many bright dots are acceptable?

There is no universal number, and a figure copied from another programme may be unachievable or too loose for the product. What matters is the combination of count, position, adjacency and viewing distance, plus whether the count is of pixels or sub-pixels. The workable approach is a numeric limit for scattered dots, a stricter rule for clusters and for the central viewing area, and a signed boundary sample for the cases the numbers cannot describe.

Should limits differ by viewing distance?

Yes, because the defect has to be visible to matter. A panel viewed at arm's length in a handheld product can tolerate marks that would be obvious on a monitor watched from a metre away. Set the inspection distance to the distance the user will actually have, state it on the condition card, and keep it identical at both the supplier's and the customer's inspection. Changing the distance later is a specification change, not an inspection convenience.

Who signs off limit samples?

The customer's quality function and the supplier's quality manager, on a record that lists each sample ID, its defect class, its verdict, the drawing revision and the viewing conditions. Sourcing and engineering usually attend the review, since they own the commercial and design consequences, but the signatures that count are the two quality functions that will apply the criterion. One named person on each side should also hold authority to approve changes to the set.

How are samples stored and referenced?

Keep one master set under controlled conditions, dark, dust-free and at stable temperature, with a named custodian and a removal log, plus a working set at each inspection site. Reference each sample by a unique ID that appears on the drawing or the acceptance clause, so an inspector can cite the exact reference used. Photographs are for identification and training only, never for the accept or reject decision, and both parties should compare their sets periodically.

×

Contact Us

(Accept word, pdf, dxf, dwg, jpg, ai, psd file, Max 10M)
captcha

By continuing to use the site you agree to our privacy policy Terms and Conditions.

I agree